Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ann Card Anaesth ; 2019 Jan; 22(1): 24-29
Article | IMSEAR | ID: sea-185808

ABSTRACT

Background: We reviewed our experience with ruptured sinus of Valsalva aneurysms (RSOV) to determine a correlation with preexisting heart failure (HF) and coexisting cardiac lesions (aortic regurgitation [AR] and ventricular septal defect [VSD]) to postoperative left ventricular (LV) dysfunction and postoperative outcomes. Materials and Methods: Retrospective review of RSOV cases over 15 years showed that RSOV repair was done in 87 patients. We looked for patients who presented with HF and patients having AR and/or VSDs. Statistical analysis was done to see if the coexisting lesions and preoperative HF were associated with postoperative LV dysfunction. Chi-square test was used on contingency table for statistical analysis. Complications in the postoperative period and prolonged Intensive Care Unit stay were noted. Results: 17% (15/87) presented with HF. Fifty-two patients had moderate to severe AR and 50 patients had VSD. Seventeen patients had postoperative LV dysfunction. The correlation of preoperative HF and coexisting lesions with postoperative LV dysfunction was not statistically significant. Two patients underwent redo surgery for residual RSOV and AR. Two patients had arrhythmias. One patient had cerebrovascular accident. No mortality was seen in the study. Conclusion: Preoperative HF and the presence of VSD and/or AR have no statistical significant correlation with postoperative LV dysfunction. As the outcome of RSOV repair is good, all patients need to undergo early repair to avoid complications.

2.
Ann Card Anaesth ; 2018 Apr; 21(2): 205-207
Article | IMSEAR | ID: sea-185716

ABSTRACT

Absent superior vena cava (SVC) is an asymptomatic congenital systemic venous anomaly which is rarely detected and compatible with normal life. Undiagnosed absent SVC may cause problems during cardiac catheterization or cardiac surgery. We present our surgical experience in a patient with tetralogy of Fallot who had undiagnosed absent SVC.

3.
Ann Card Anaesth ; 2016 Jan; 19(1): 68-75
Article in English | IMSEAR | ID: sea-172283

ABSTRACT

Context: We hypothesized that reduced oropharyngolaryngeal stimulation with video laryngoscopes would attenuate hemodynamic response to laryngoscopy and intubation. Aim: Comparison of hemodynamic response to laryngoscopy and intubation with video laryngoscopes and Macintosh (MC) laryngoscope. Setting and Design: Superspecialty tertiary care public hospital; prospective, randomized control study. Methods: Sixty adult patients undergoing elective coronary artery bypass grafting (CABG) were randomly allocated to three groups of 20 each: MC, McGrath (MG), and Truview (TV). Hemodynamic parameters were serially recorded before and after intubation. Laryngoscopic grade, laryngoscopy, and tracheal intubation time, ST segment changes, and intra‑/post‑operative complications were also recorded and compared between groups. Statistical Analysis: SPSS version 17 was used, and appropriate tests applied. P < 0.05 was considered significant. Results: Heart rate and diastolic arterial pressure increased at 0 and 1 min of intubation in all the three groups (P < 0.05) while mean arterial pressure increased at 0 min in the MG and TV groups and at 1 min in all three groups (P < 0.05). A significant increase in systolic arterial pressure was only observed in TV group at 1 min (P < 0.05). These hemodynamic parameters returned to baseline by 3 min of intubation in all the groups. The intergroup comparisons of all hemodynamic parameters were not significant at any time of observation. Highest intubation difficulty score was observed with MC (2.16 ± 1.86) as compared with MG (0.55 ± 0.88) and TV (0.42 ± 0.83) groups (P = 0.003 and P = 0.001, respectively). However, duration of laryngoscopy and intubation was significantly less in MC (36.68 ± 16.15 s) as compared with MG (75.25 ± 30.94 s) and TV (60.47 ± 27.45 s) groups (P = 0.000 and 0.003, respectively). Conclusions: Video laryngoscopes did not demonstrate any advantage in terms of hemodynamic response in patients with normal airway undergoing CABG.

4.
Ann Card Anaesth ; 2015 Jul; 18(3): 433-436
Article in English | IMSEAR | ID: sea-162397

ABSTRACT

Perioperative management of a patient with Dandy–Walker malformation (DWM) with tetralogy of Fallot (TOF), patent ductus arteriosus, and pulmonary artery stenosis is a great challenge to the anesthesiologist. Anesthetic management in such patients can trigger tet spells that might rapidly increase intracranial pressure (ICP), conning and even death. The increase in ICP can precipitate tet spells and further brain hypoxia. To avoid an increase in ICP during TOF corrective surgery ventriculo‑peritoneal (VP) shunt should be performed before cardiac surgery. We present the first case report of a 11‑month‑old male baby afflicted with DWM and TOF who underwent successful TOF total corrective surgery and fresh autologous pericardial pulmonary valve conduit implantation under cardiopulmonary bypass after 1 week of VP shunt insertion.


Subject(s)
Anesthesia, General/methods , Cardiopulmonary Bypass/methods , Dandy-Walker Syndrome/epidemiology , Dandy-Walker Syndrome/surgery , Heart Valve Prosthesis Implantation , Humans , Infant , Male , Perioperative Care/methods , Pulmonary Artery/transplantation , Pulmonary Valve/transplantation , Stents , Tetralogy of Fallot/epidemiology , Tetralogy of Fallot/surgery , Transplantation, Homologous
5.
Ann Card Anaesth ; 2014 Apr; 17(2): 141-144
Article in English | IMSEAR | ID: sea-150314

ABSTRACT

A 36‑year‑old male patient presented with the complaints of palpitations and breathlessness. Preoperative transthoracic echocardiography (TTE) revealed a bicuspid aortic valve; severe aortic regurgitation with dilated left ventricle (LV) and mild LV systolic dysfunction (ejection fraction 50%). He was scheduled to undergo aortic valve replacement. History was not suggestive of infective endocarditis (IE). Preoperative TTE did not demonstrate any aortic perivalvular abscess. Intraoperative transesophageal echocardiography (TEE) examination using the mid‑esophageal (ME) long‑axis view, showed an abscess cavity affecting the aortic valve, which initially was assumed to be a dissection flap, but later confirmed to be an abscess cavity by color Doppler examination. The ME aortic valve short‑axis view showed two abscesses; one was at the junction of the non‑coronary and left coronary commissure and the other one above the right coronary cusp. Intraoperatively, these findings were confirmed by the surgeons. The case report demonstrates the superiority of TEE over TTE in diagnosing perivalvular abscesses.


Subject(s)
Abscess/diagnosis , Abscess/diagnostic imaging , Adult , Aortic Valve/surgery , Echocardiography/methods , Echocardiography, Transesophageal/methods , Endocarditis, Bacterial/complications , Heart Valve Diseases/diagnosis , Heart Valve Diseases/diagnostic imaging , Humans , Male , Prosthesis-Related Infections/complications
SELECTION OF CITATIONS
SEARCH DETAIL